500m 115mm2 Electric Power Kabel Hittebestendige ASTM B 399 Norm

Basisinformatie
Plaats van herkomst: CHINA
Merknaam: OEM
Certificering: 3C; ISO 9001:2015, ISO 14001:2005, OHSAS 18001:2007
Min. bestelaantal: 300 meters
Prijs: Negotiation
Verpakking Details: Houten trommel, hout en staaltrommel, als verzoek van de klant
Levertijd: 15-20 werkdagen of Onderhandeling
Betalingscondities: T/T, L/C, D/P, het Westenunie, Paypal, Veilige Betalingen
Materiaal: aluminium en staal Kern: Normaal of Aangepast
De Lengte van de kabeltrommel: 300~1000meter per trommel characted: Naakte Leider
Nominaal Gebied: 18.4~1439 Trommel: Houten of ijzer
Hoog licht:

115mm2 Electric Power Cable

,

115mm2 outdoor electrical cable

,

500m Electric Power Cable

British standard supplier 100 mm2-1000 mm2 ACSR, Aluminum conductor steel reinforced

 

 

APPLICATION: ACSR is mainly used as bare overhead transmission cable and as primary and secondary distribution cable. It is also suitable for laying across basins, rivers and valleys where special geographical teatures exist.

 

 

STANDARD

Basic design to BS 3242 / BS EN 50182 / IEC 61089 / ASTM B 399/B 399M / DIN 48201 -6 standards.

 

CONSTRUCTION ACSR cable bvconsists of aluminum wires. The aluminum wires are concentrically stranded.

This section deals with heat-treatable magnesium silicon type aluminium alloys to the applicable International Standard, the electrical and mechanical properties of which all fall within the values suggested by relevant standard. Conductors to all other recognized specifications can also be supplied. The alloys referred to have higher strength but lower conductivity than pure aluminium. Being lighter, alloy conductors can sometimes be used to advantage in place of the more conventional ACSR; Having lower breaking loads than the later, their use becomes particularly favourable when ice and wind loadings are low.

 

(*) Note: The values of current rating mentioned in above Table are based on wind velocity of 0.6 metre/second, solar heat radiation of 1200 watt/metre2, ambient temperature of 50° C & conductor temperature of 80°C.

 

ELECTRICAL PROPERTIES

density@20ºC 2.70 kg/dm
Temperature Coefficient@20°C 0.00360 (°C)
resistivity@20°C 0.0326 Ohms mm2/m
linear Expansivity

23 x10-6 (°C)

 

SERVICE CONDITIONS

Ambient Temperature -5°C - 50°C
Wind Pressure 80 – 130kg/m
Seismic Acceleration 0.12 - 0.05g
Isokeraunic level 10 – 18
relative Humidity 5 – 100%


 

 

CONSTRUCTION PARAMETERS

• IEC 60189

Code Nominal Area Stranding Overall Diameter Weight Rated Strength Electrical Resistance Current Rating*
  mm2 No.x mm mm Kg/Km KN Ω/Km A
16 18.4 7/1.83 5.49 50.4 5.43 1.7896 86
25 28.8 7/2.29 6.87 78.7 8.49 1.1453 113
40 46 7/2.89 8.67 125.9 13.58 0.7158 151
63 72.5 7/3.63 10.89 198.3 21.39 0.4545 200
100 115 19/2.78 13.9 316.3 33.95 0.2877 266
125 144 19/3.10 15.5 395.4 42.44 0.2302 305
160 184 19/3.51 17.55 506.1 54.32 0.1798 355
200 230 19/3.93 19.65 632.7 67.91 0.1439 407
250 288 19/4.39 21.95 790.8 84.88 0.1151 466
315 363 37/3.53 24.71 998.9 106.95 0.0916 535
400 460 37/3.98 27.86 1268.4 135.81 0.0721 618
450 518 37/4.22 29.54 1426.9 152.79 0.0641 663
500 575 37/4.45 31.15 1585.5 169.76 0.0577 706
560 645 61/3.67 33.03 1778.4 190.14 0.0516 755
630 725 61/3.89 35.01 2000.7 213.9 0.0458 809
710 817 61/4.13 37.17 2254.8 241.07 0.0407 866
800 921 61/4.38 39.42 2540.6 271.62 0.0361 928
900* 1036 91/3.81 41.91 2861.1 305.58 0.0321 992
1000* 1151 91/4.01 44.11 3179 339.53 0.0289 1051
1120* 1289 91/4.25 46.75 3560.5 380.27 0.0258 1118
1250* 1439 91/4.49 49.39 3973.7 424.41 0.0231 1185

     